Connecting the terminal board
The appliance has a six-pole terminal
board. The jumpers (bridges) are set for
operation on a 400 V three-phase with a
neutral wire.
1 = 45 mm
2 = 45 mm
3 = 60 mm
4 = 60 mm
= 70 mm
1 2 3 4 5
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange
the jumpers on the terminal board (refer to
the connection diagram below). Connect
the ground cable to the terminal. After you
connect the supply cable to the terminal
board, attach it with a junction clamp.
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
230V 3~
230V 1~
400V 2N~
400V 3N~
L1
L1 N
L2
L1 N
N
L2
L3
L1
L2
L3
PE
PE
PE
PE
ENERGY EFFICIENCY
Product Fiche and information according to EU 65-66/2014
Supplier's name Progress
Model identification PHN23100X
Energy Efficiency Index 103.8
Energy efficiency class A
Energy consumption with a standard load, conventional
mode
0.83 kWh/cycle
Energy consumption with a standard load, fan-forced
mode
0.82 kWh/cycle
Number of cavities 1
Heat source Electricity
Volume 57 l
Type of oven Built-Under Oven
Mass 28.8 kg