Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05 VV-F,
H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the total
power on the rating plate.
Connecting the terminal board
The appliance has a six-pole terminal
board. The jumpers (bridges) are set for
operation on a 400 V three-phase with a
neutral wire.
L 1 – 2 – 3 = phase cables
N 4 = neutral cable
= earth cable
If the mains voltage is different, rearrange
the jumpers on the terminal board (refer to
the connection diagram below). Connect
the ground cable to the terminal. After you
connect the supply cable to the terminal
board, attach it with a junction clamp.
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
1 2 3 4 5
230V 3~
230V 1~
400V 2N~
400V 3N~
L1
L1 N
L2
L1 N
N
L2
L3
L1
L2
L3
PE
PE
PE
PE
ENERGY EFFICIENCY
Product Fiche and information according to EU 65-66/2014
Supplier's name Progress
Model identification PHN13000X
Energy Efficiency Index 103.8
Energy efficiency class A
Energy consumption with a standard load, conventional
mode
0.83 kWh/cycle
Energy consumption with a standard load, fan-forced
mode
0.82 kWh/cycle
Number of cavities 1
Heat source Electricity
Volume 57 l